    针对延期药延期时间精度较低、长贮性能差的问题, 实验研究了湿法压药对B-BaCrO4延期药精度的影响。结果表明,无论是在常温,还是在高低温(-6 ℃、60 ℃)和长贮(70 d)条件下,湿法压药的B-BaCrO4延期药均具有较好的精度。

    Abstract:

    In order to solve the low precision of delay-time and bad long-storage property of delay composition,the delay-time precisions of B-BaCrO delay composition pressed by wet method and dry method were studied with high-low temperature test and long-storage test. The results show that the delay-time precision of B-BaCrO4 delay composition pressed by wet method is better than that by dry method at the room temperature,high or low temperature (-6 ℃,60 ℃)or in long-storage test(70 d).