CHINESE JOURNAL OF ENERGETIC MATERIALS
+高级检索
微波强化Fenton降解偏二甲肼废水
DOI:
作者:
作者单位:

(第二炮兵工程大学, 陕西 西安 710025)

作者简介:

张淑娟(1966-),女,博士,副教授,主要从事特种污染源的监测与治理。e-mail: sjzhang66@163.com

通讯作者:

基金项目:


Degradation of Unsymmetrical Dimethylhydrazine with Microwave Enhanced Fenton
Author:
Affiliation:

(The Second Artillery Engineering University, Xi′an 710025, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    采用微波强化Fenton工艺处理了偏二甲肼废水,考察了微波功率、H2O2投加量、pH值、Fe2+与H2O2摩尔比等因素对废水处理效果的影响,通过正交实验确定了该工艺的最佳条件。结果表明,在微波功率280 W,H2O2(68.5 g·L-1)投加量4.0 mL、水样pH=4.0、Fe2+与H2O2摩尔比1:16、反应时间8.0 min的条件下,偏二甲肼废水COD去除率可达98.4%。

    Abstract:

    The unsymmetric dimethyl hydrazine (UDMH) wastewater was degraded by the microwave (MW) enhanced Fenton, and the effect factors, such as MW power, dosage of H2O2, pH, Fe2+:H2O2 molar ratio on wastewater treatment were studied. The best degradation conditions were determined by the orthogonal experiment. Results show that, the chemical oxygen demand(COD) removal rate could be 98.4% on condition that MW power is 280 W, H2O2 (68.5 g·L-1) dosage 4.0 mL, pH 4.0, Fe2+:H2O2 molar ratio 1:16 and reaction time 8.0 min.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

张淑娟,陈啸剑,吴婉娥,等.微波强化Fenton降解偏二甲肼废水[J].含能材料, 2013, 21(4):455-459.
ZHANG Shu-juan, CHEN Xiao-jian, WU Wane, et al. Degradation of Unsymmetrical Dimethylhydrazine with Microwave Enhanced Fenton[J]. Chinese Journal of Energetic Materials, 2013, 21(4):455-459.

复制
历史
  • 收稿日期: 2012-03-17
  • 最后修改日期: 2012-05-21
  • 录用日期: 2013-01-06
  • 在线发布日期: 2013-08-29
  • 出版日期: