    摘要:

    为了安全、准确地监测火炸药粉体静电放电引发燃烧爆炸风险, 针对静电场强监测、法拉第筒电荷量监测及感应电流积分电荷量监测等三种方法, 建立了相应的实验装置。采用代用材料方式, 对不同方法获取静电场数据的准确性、静电带电监测的可靠性进行了对比实验研究, 并评估了监测系统的安全性。结果表明, 在料仓中粉堆高度为200 mm时, 粉堆表面监测到的场强(2160 kV)仅为粉堆底部场强(14709 kV)的1/7、粉堆高度为100 mm时粉堆表面的场强数据与标定数据相差20倍, 不能实现对静电放电风险的准确、可靠监测。法拉第筒电荷量监测方法及感应电流积分电荷量监测方法的监测数据准确, 可以实现对静电场强的可靠监测, 但法拉第筒电荷量监测系统自身存在静电放电风险, 而感应电流积分电荷量监测系统安全性较好。

    Abstract:

    To safely and accurately monitor the risk of combustion and explosion of explosive and propelant powder caused by electrostatic discharge, aiming at three kinds of monitoring methods, including field strength monitoring and Faraday cylinder charge quantity monitoring and induced current integral charge quantity monitoring, corresponding testing devices were established. The contrast testing study on the accuracy of the electrostatic field monitoring data obtained by different methods and the reliability of the electrostatic monitoring was performed by the way of substitute material and the safety of the monitoring system was evaluated. Results show that when powder pile height in storage bin is 200 mm, the field strength monitored by powder pile surface is 2160 kV, which is only 1/7 of the field strength of 14709 kV in base of powder pile, when powder pile height is 100 mm, the field strength data of powder pile surface is 20 times of the calibration data, it can not achieve accurate and reliable monitoring of electrostatic discharge risk. The monitoring data of Faraday cylinder charge quantity monitoring method and induced current integral charge quantity monitoring method are accurate, they can realie the reliable monitoring of electrostatic field, but Faraday cylinder charge quantity monitoring system itself exists the risk of electrostatic discharge, whereas induced current integral charge quantity monitoring system has good safety.

    参考文献
    相似文献
    引证文献
文章指标
  • PDF下载次数:
  • HTML阅读次数:
  • 摘要点击次数:
  • 引用次数:
引用本文

卫水爱,白春华.火炸药粉体静电带电监测方法对比实验研究[J].含能材料, 2017, 25(6):515-519. DOI:10.11943/j. issn.1006-9941.2017.06.012.
WEI Shui-ai, BAI Chun-hua. Contrast Testing Study of Electrostatic Monitoring Method for Energetic Powders[J]. Chinese Journal of Energetic Materials, 2017, 25(6):515-519. DOI:10.11943/j. issn.1006-9941.2017.06.012.

复制
历史
  • 收稿日期: 2016-11-07
  • 最后修改日期: 2017-02-07
  • 录用日期: 2017-02-22
  • 在线发布日期: 2017-06-22
  • 出版日期: 2017-06-23